Safe boiler operation fundamentals download pdf free
Readers will learn how to develop emergency action plans and fire prevention plans, implement effective alarm and detection systems and fire extinguishment systems, and develop a comprehensive fire program management plan that is in compliance with Federal Emergency Management Agency, Occupational Safety and Health Administration, Environmental Protection Agency, and National Fire Protection Association standards.
Each chapter includes a chapter summary and sample problems, making this an ideal training tool in the workplace or the classroom. Answers to chapter questions and a comprehensive glossary and index are provided at the end of the book. K Das, A. K Das P. K Das.
Author : P. This book is intended to meet the requirements of the fresh engineers on the field to endow them with indispensable information, technical know-how to work in the power plant industries and its associated plants. The book provides a thorough understanding and the operating principles to solve the elementary and the difficult problems faced by the modern young engineers while working in the industries.
The problem generally occurs in the power plants during operation and maintenance. It has been explained in a lucid language. Brumbaugh James E. Author : James E. A reference you'll warm up to From the background and basics of heating systems to the newest chip-based technology, this first volume of Audel's HVAC Library gives you comprehensive information you need on the job. Whether you're installing, servicing, repairing, or troubleshooting an old or new heating system, you'll find what you're looking for, from wood and coal furnace maintenance to new calculations and the latest environmental technologies and regulations.
Boiler Operations Boiler Operations M. Murgai M. Author : M. The fourth edition of the book is richer in contents presenting updated information on the fundamental aspects of various processes related to thermal power plants. The major thrust in the book is given on the hands-on procedure to deal with the normal and emergency situations during plant operation.
Beginning from the fundamentals, the book, explores the vast concepts of boilers, steam turbines and other auxiliary systems.
Following a simple text format and easy-to-grasp language, the book explicates various real-life situation-related topics involving operation, commissioning, maintenance, electrical and instrumentation of a power plant. Dealing with all the latest coverage, the book is written to address the requirements of the undergraduate students of power plant engineering. The book will also be of immense use to the students of postgraduate diploma course in thermal power plant engineering.
Sauselein Theodore B. Author : Theodore B. Written for boiler operators, each chapter covers the basic underlying theory that introduces the subject to the beginner and acts as a review for the more experienced professional. It includes multiple-choice, essay, and number problems similar to actual exam questions. Problems include enough steps to clarify reasoning used to determine each answer. Rao K. Author : K. This is Volume 1 of the fully revised second edition.
Organized to provide the technical professional with ready access to practical solutions, this revised, three-volume, 2,page second edition brings to life essential ASME Codes with authoritative commentary, examples, explanatory text, tables, graphics, references, and annotated bibliographic notes. The main question under examination is, "What factors affected these developments? The thesis shows how the electrical needs of the economy, widespread developments in technology, and financial considerations have enabled the coal fired boiler to remain the most important way of generating power [.
This GL O MACS Steam Boilers training seminar will focus on the study of correct operation and regular routine maintenance to ensure that boiler plant remains at peak efficiency, keeping running costs to a minimum. The training seminar provides participants with the best practices and procedures of boilers operation and maintenance.
The goal of this GL O MACS training seminar is to ensure participants gain a comprehensive understanding of commercial, industrial and utility boiler systems. Boiler inspections, maintenance, operating controls testing, and troubleshooting will all be discussed. Also, the protection and burner management system will be discussed. This GL O MACS Steam Boilers training seminar will be delivered along workshop principles with formal lectures, video clips, multimedia illustrations and interactive worked examples.
File Name: safe boiler operation fundamentals pdf. Boiler Parts and Their Functions. Easy way to learn html and css pdf. There are five types of flame detectors when used with combustion heating equipment.
They are: 1. CAD Cell Cadmium Sulfide the photocell changes resistance as cadmium sulfide is responsive to light 2. Infrared IR Light is sensitive to the infrared radiation emitted by the combustion of fuels such as natural gas, oil and coal. Photocell sensors that detect visible light 4.
Ultraviolet UV Light sensors that detect ultraviolet radiation emitted from all flames 5. Flame Rod is a sensor that has the ability to use a small amount of current, which is conducted by and through the flame.
The double block and bleed gas train uses redundant safety shut-off gas valves blocking valves to provide a positive method of preventing gas flow to the burner. Between the two safety shut-offs, a bleed valve allows any gas in the line to safely flow out of the building. Most boiler accidents are caused by operator error and poor maintenance.
The Chief Engineer of a boiler plant holds the responsibility for directing boiler operations, procedures and maintenance. Log sheets are a paper record of boiler operation and maintenance, and should be used in all boiler rooms to help ensure safe operation. A log sheet will specify the task to be performed, such as blowing down the low water cut-out LWCO , and the operator can then mark the sheet to show that this operation was completed.
If the boiler is to be placed out of service for an extended period of time, proper lay-up procedures are required and must be followed. A low water condition is the most common cause of boiler failure. The first thing a boiler operator should do when entering the boiler room or taking over boiler operation is to check the NOWL.
An automatic boiler feedwater regulator is designed to maintain the proper water level in the boiler. A low water alarm in the system is designed to alert the boiler operator of a low water level. In the event of a low water alarm, secure the fire first before adding water to the boiler.
The gage glass sight glass is a tube that indicates the water level in the boiler. It is installed either directly on the boiler or on the water column.
It is connected at the top into the steam section of the boiler and at the bottom into the water section, thus showing the true boiler water level. The water level in the gage glass is tested by opening and then closing the gauge glass blowdown valve.
In addition to the gage glass, some boilers also have try-cocks installed to indicate the water level. The three try-cocks which are drain valves are placed on the water column at various levels. Blowdowns Boiler blowdown is removal of water from the boiler. It is done in order to remove the amount of solids in the water, and is performed as either bottom sludge blowdown, or continuous surface blowdown.
The blowdown frequency and duration is primarily determined by the boiler water analysis. The water quality will vary greatly based on boiler type and size, amount of condensate return, and boiler water treatment program. Inspections A boiler internal inspection is performed to allow the boiler inspection a view of all internal surfaces, i. The boiler is taken off line, cooled, drained, opened and cleaned in preparation for the internal boiler inspection. All hand holes and manholes are opened, and the low water cut-outs are opened and cleaned.
This is a water- pressure test of new installations and repaired boilers. A handhole provides access to the waterside of the firetube boiler for inspection. Boiler trim, Valves, Fittings, and Controls Boiler trim is the controls and fittings used to operate the boiler.
The trim determines whether the pressure vessel is used for steam or hot water production. Trim includes devices such as the low water cut-out, the gage glass sometimes called the sight glass , the pressure gauge, etc. Valves The safety valve also referred to a relief valve, pop-off valve, or safety relief valve provides protection to the pressure vessel from over pressurization and is the primary safety control on all boilers. They must be of sufficient size capacity to keep the boiler from developing more steam pressure than the valve can relieve, and must be set at or below the boiler MAWP Maximum Allowable Working Pressure.
Valve pressure settings cannot be changed by plant personnel, but must be calibrated by a certified repair facility. There should be no shut off valves between the boiler and the pop-off valve. Boilers with more than sq ft. Safety valves are spring loaded valves and should be regularly tested by the boiler operator on duty, unless plant policy states otherwise.
Testing a safety relief valve is performed by simply lifting the test lever on the side of the valve. Prior to the test, determine that the valve discharge is piped to a safe place.
A gate valve is an isolation valve, and is used only for the purpose of stopping or allowing flow. Gate valves are used as steam stop valves, blowdown valves, etc. Gate valves should always be fully open or completely closed, never in- between. The stem and yoke are outside the valve body. A rising stem valve allows the boiler operator to know the position of the valve by looking at the stem.
If the stem is extended up or out the valve is open. In an open position, the valve provides no resistance to the flow of steam. If the stem is down or in, the valve is closed. These valves are typically seen in steam lines. A globe valve is a modulation valve, not an isolation valve. A globe valve disrupts the flow of the fluid, even in the fully open position. A check valve allows flow in one direction only.
These are often seen in feedwater lines between the pumps and the boiler. When opening any manual valve, the boiler operator should open the valve slowly in order to prevent water hammer. The control opens the burner circuit, stopping the burner if it senses a low-water level. Controls may also operate the feedwater pump or valve or a make-up water valve as well as the burner. They are called dual or triple element controls.
If the LWCO is mechanical a float , it must be blown down drained on a regular basis to prevent sediment from accumulating in the float chamber. If it is electronic, this procedure is not necessary. Both types should be disassembled and cleaned at least once per year. Testing the LWCO is done by draining the float chamber to see if the burner stops, called a controlled blowdown test. This test should be performed on a regular basis.
The electronic control is tested by the evaporation or slow drain method. This test requires the feedwater supply to be secured, and the burner is allowed to operate normally. If the control is functioning properly the burner will shut off when the water level goes below the NOWL.
As the water supply has been shut off to the boiler, this test is extremely dangerous and should only be done by qualified operators. A feedwater pump pumps the water from the feedwater system to the boiler.
Calcium and magnesium are the most common of the minerals found in water supplies. Water may also contain silica, iron, and other trace minerals that vary by geographic location. The build up of scale on a heating surface insulates and overheats metal surfaces, reducing the life of the boiler and making it less efficient. Additionally, the scale can travel downstream of the boiler clogging ports and surfaces of other equipment.
Hardness of water is the measurement of mineral content or scale forming salts in water. Hard water is water than contains more than 25 ppm of scale-forming minerals.
Soft Water is water with low mineral content. Conductivity is a measurement of how many solids are in the water, based on the conductance ability to conduct electricity of the water. The more solids, the better the water conducts electricity and the more scale will build up.
Water treatment programs use conductivity as a way to measure and control the solids level in the boiler water.
0コメント